再生铜轧板常因成分偏析,打平后表面硬度不均(偏差 HV 20–40),锤痕深浅不一、局部回弹大。排查:①用便携硬度计按 30 mm 间距网格测点,画出硬度分布图;②对高硬区做局部退火(650 ℃×8 min)而非整板退火;③若反复出现橘皮说明偏析严重,换批或加一道 10% 冷轧+退火匀化。记录每批料硬度基线以定锤击力度。

Recycled rolled copper often shows composition segregation, giving uneven hardness after planishing (HV spread 20–40): inconsistent marks and patchy springback. Check: (1) map hardness on a 30 mm grid with a portable tester; (2) locally anneal hard zones (650 °C × 8 min) instead of the whole sheet; (3) recurring orange-peel means severe segregation—change batch or add a 10% cold roll plus anneal to homogenise. Log a hardness baseline per batch to set hammer force. ---